Výkonné stroje osazené procesory AMD Opteron.

Podporované OS (Certifikované)

  • Solaris 9 x86 4/04
  • Red Hat Enterprise Linux 3 AMD64
  • Microsoft Windows 2000 (WHCL-certified)
  • Microsoft Windows Server 2003 (WHCL-certified)

64-Bit:

  • Solaris 10 x86
  • SuSE Linux Enterprise Server 8 AMD64
  • Red Hat Enterprise Linux 3 AMD64

Parametr V20z V40z
CPU AMD Opteron 200 Series AMD Opteron 800 Series
Počet CPU 1 až 2 2 nebo 4
Výška 1U 2U
RAM - 4banky/CPU až 16GB až 32 GB
Lan 2x10/100/1000 2x10/100/1000
Managment 2x10/100 LAN 2x10/100 LAN
SCSI interní Single Channel Ultra320 Single Channel Ultra320
HDD max 2 x U320 max 6 x U320
DVD-ROM/fdd ano ano
Power Supply 1 (465W) 2 (760W)



Instalace Windows - drivery SCSI

Proč instalovat Win? Protože to občas někdo chce....

Pokud by někdo chtěl instalovat Windows (jedno v jaké verzi) je pořeba dodat Windows driver na SCSI řadič. To můžete udělat dvěma zpúsoby:
1. Nakopírovat na disketu a podstrčit jí při instalaci.
2. Upravit instalační CD tak aby v sobě mělo drivery.

SCSI drivery pro tyto stroje jsou k nalezení na webu Sun, nebo na http://sun.vydrar.net/V20z/.
Pokud se rozhodnete integrovat drivery do instalačního CD, můžete to udělat pomocí programu nLite. V sekci Download naleznete také .NET Framework 1.1 Runtime, který je k běhu programu potřeba. Integrace Driverů je velice snadná, výsledkem bude ISO obraz instalačního CD, který vypálíte a můžete bootovat s integrovanými drivery :).

Servisní procesor
Přesto že je V20z a V40z ze světa "PC", disponuje servisním CPU.
Jedná se o jednoduchý systém v systému. Jakmile zapnete zdroj, naběhne tento servisní CPU.
Tento malý počítač má 16MB Flash paměť a 64 MB RAM.
Pokud by někoho zajímalo co je uvnitř za procesor, tak: XPC860xxZPnnD4. Takt úctyhodných 64 MHz. Pokud se chcete připojit na servisní procesor (SP) napřímo, můžete to udělat pomocí seriového null modemu. Parametry: 115200,8N1. Jakmile zapnete zdroj na V20z, můžete sledovat boot SP:

PPCBOOT Starting

CPU:   XPC860xxZPnnD4 at 64 MHz: 4 kB I-Cache 4 kB D-Cache FEC present
Board: Service Processor Stage 1 - Rev. 0
DRAM:  64 MB
FLASH: 16 MB
In:    serial
Out:   serial
Err:   serial
Product_ID = 0xff (255)
PPCBOOT revision = V2.1.0.16
Board_Revision = 0x05 (5)
PRS revision = 0x5c (92)
Hit any key to stop autoboot:  0 
## Booting image at 40080000 ...
   Image Name:   Linux Kernel for SP
   Image Type:   PowerPC Linux Kernel Image (gzip compressed)
   Data Size:    681511 Bytes = 665 kB = 0 MB
   Load Address: 00000000
   Entry Point:  00000000
   Verifying Checksum ... OK
   Uncompressing Kernel Image ... OK
## Loading RAMDisk Image at 40180000 ...
   Image Name:   Simple Ramdisk Image
   Image Type:   PowerPC Linux RAMDisk Image (gzip compressed)
   Data Size:    4165974 Bytes = 4068 kB = 3 MB
   Load Address: 00000000
   Entry Point:  00000000
   Verifying Checksum ... OK
   Loading Ramdisk to 03b66000, end 03f5f156 ... OK
Linux version 2.4.18 (navin.boppuri@southern) (gcc version 2.95.3 20010315 (release/MontaVista)) #1 Fri Apr 1 15:23:25 CST 2005
On node 0 totalpages: 16384
zone(0): 16384 pages.
zone(1): 0 pages.
zone(2): 0 pages.
Kernel command line: root=/dev/ram rw devfs=
Decrementer Frequency = 240000000/60
Calibrating delay loop... 63.69 BogoMIPS
Memory: 58580k available (1264k kernel code, 456k data, 64k init, 0k highmem)
Dentry-cache hash table entries: 8192 (order: 4, 65536 bytes)
Inode-cache hash table entries: 4096 (order: 3, 32768 bytes)
Mount-cache hash table entries: 1024 (order: 1, 8192 bytes)
Buffer-cache hash table entries: 4096 (order: 2, 16384 bytes)
Page-cache hash table entries: 16384 (order: 4, 65536 bytes)
POSIX conformance testing by UNIFIX
Linux NET4.0 for Linux 2.4
Based upon Swansea University Computer Society NET3.039
Initializing RT netlink socket
Starting kswapd
Journalled Block Device driver loaded
devfs: v1.10 (20020120) Richard Gooch (rgooch@atnf.csiro.au)
devfs: boot_options: 0x1
JFFS2 version 2.1. (C) 2001 Red Hat, Inc., designed by Axis Communications AB.
CPM UART driver version 0.03
ttyS00 at 0x0280 is a SMC
ttyS01 at 0x0380 is a SMC
pty: 256 Unix98 ptys configured
block: 128 slots per queue, batch=32
RAMDISK driver initialized: 16 RAM disks of 23552K size 1024 blocksize
eth0: FEC ENET Version 0.2, FEC irq 3, addr 00:09:3d:10:5d:77
SLIP: version 0.8.4-NET3.019-NEWTTY (dynamic channels, max=256).
loop: loaded (max 8 devices)
sp flash device: 1000000 at 40000000
 Amd/Fujitsu Extended Query Table v1.1 at 0x0040
number of CFI chips: 1
Creating 12 MTD partitions on "Service Processor flash device":
0x00000000-0x00040000 : "PPCBOOT"
0x00040000-0x00080000 : "Environment"
0x00080000-0x00180000 : "Linux Kernel"
0x00180000-0x00600000 : "BASE file system"
0x00600000-0x00d80000 : "Value Add file system Image"
0x00ec0000-0x00ee0000 : "VPD Area - Protected"
0x00ee0000-0x00f00000 : "Diagnostics Reserved"
0x00f00000-0x01000000 : "Flash file system"
0x00000000-0x00ea0000 : "Entire flash"
0x00d80000-0x00dc0000 : "Custom Area"
0x00dc0000-0x00e60000 : "Unused Area"
0x00e60000-0x00ea0000 : "PPCBOOT Update Area"
NET4: Linux TCP/IP 1.0 for NET4.0
IP Protocols: ICMP, UDP, TCP
IP: routing cache hash table of 512 buckets, 4Kbytes
TCP: Hash tables configured (established 4096 bind 4096)
ip_conntrack (512 buckets, 4096 max)
ip_tables: (C) 2000-2002 Netfilter core team
NET4: Unix domain sockets 1.0/SMP for Linux NET4.0.
RAMDISK: Compressed image found at block 0
Freeing initrd memory: 4068k freed
VFS: Mounted root (ext2 filesystem).
Mounted devfs on /dev
Freeing unused kernel memory: 64k init
INIT: version 2.78 booting
Mounting local filesystems...
Booted from ramdisk..
Service Processor GPIO driver, ver. V2.3.0.15
Service Processor PRS Low-Level driver, ver. 2.0a
Service Processor SPI driver, ver. V2.3.0.15
JNET driver online.
Configuring iptables
Hostname: localhost.localdomain
Setting up IP spoofing protection: rp_filter.
Disable TCP/IP Explicit Congestion Notification: done.
Configuring network interfaces: done.
Starting portmap daemon: portmap.
ln: accessing `/usr/local/config/factory_ssl_server.key': No such file or directory
ln: accessing `/usr/local/config/factory_ssl_server.crt': No such file or directory
INIT: Entering runlevel: 2
Starting metalog for logging services
Starting internet superserver: inetd.
Starting system management applications...
Generating public/private rsa key pair.
Your identification has been saved in /pstore/ssh/ssh_host_rsa_key.
Your public key has been saved in /pstore/ssh/ssh_host_rsa_key.pub.
The key fingerprint is:
15:d1:04:af:0a:e5:0a:51:4a:b1:e8:51:e5:10:ac:49 root@localhost
Generating public/private rsa1 key pair.
Your identification has been saved in /pstore/ssh/ssh_host_key.
Your public key has been saved in /pstore/ssh/ssh_host_key.pub.
The key fingerprint is:
af:21:50:e9:3c:cd:74:a1:36:ca:6d:51:35:66:35:d6 root@localhost
Starting OpenBSD Secure Shell server: sshd.

localhost login:

Co z toho můžete vyčíst:
Linux version 2.4.18
Po startu se generují klíče pro ssh

Konfigurace serveru po nabootovaní SP:
Můžete použít DHCP, nebo mu pomocí tlačítek u LCD nastavit pevnou IP adresu, masku a gw.
Jakmile má server svou IP adresu, je možné s k němu SSHáčknout a pokračovat v nastavování.

Založení prvního uživatele:
Pokud je SP v defaulním "prazdném" nastavení, je možné se přihlásit jako uživatel setup s prázdným heslem. Jakmile se přilogujete, budete vyzváni k založení nového uživatele a zadání hesla. Jakmile zadáte požadované údaje, budete odlogováni a uživatel setup přestane být funkční.

Update SP a Biosu:
Je nutné stáhnout příslušné soubory z webu. Pro update Biosu budete potřebovat NFS server, pro update SP je nutné mimo NFS mít ještě java server.
Návod jak na to je popsán na sunsolve.sun.com.

Ovládání stroje pomocí SP:

Příkaz SP Význam
platform get power state Vypsání stavu stroje (On,Off)
platform set power state off Vypnutí stroje, SP běží dál
sp add mount -r NFSSRV:/nfs_adresar -l /lokalni_adresar Mount remote adresáře
sp get mounts Výpis namountovaných adresářů
sp delete mount Odmountování namountovaných adresářů
diags start Start diagnostických testů
diag get state Zjištění stavu testů
diag get tests Vylistování co vše je možné provést za testy